Check the work
Who this page is for. The story page makes a claim: a day of AI questions costs about a teaspoon of water and under two minutes of television. This page is the receipt for it. It walks through every number in the order it was worked out, with the formula, the source, and what each figure does and doesn't count, so that an engineer, a journalist or a determined skeptic can rebuild the whole thing and find any mistake.
You don't need to read it to trust the story page; you need to know it exists. If you're here because something on the story page didn't sit right, start with what would change these conclusions, which says up front where the argument is weakest. If you just want the numbers, they're in the appendix and downloadable below.
This is not a bibliography. It is the derivation, written out in the order it was actually done, so that someone can read it start to finish and rebuild every number on the story page. Every figure carries a scope tag, because most public confusion on this subject comes from comparing figures of different scope. Every number is a link to its entry in the appendix at the bottom. The story page shows US units; the verified metric values are here and on every source chip. Assumptions marked adjustable are shared with the story page.
Dataset last verified . Download the full set as JSON or CSV.
1. The building
The model starts from a reference design rather than from a published per-prompt figure, because a building can be audited and a per-prompt figure cannot. The reference is a Basis of Design for a 100 MW facility, Rev 03-S. Critical IT means the power available to the computing equipment itself, after the facility's own overhead is excluded. Of that, 80% goes to GPU compute, 80 MW; the rest is storage and network.
The compute is entirely GB300 NVL72 racks. A rack draws 145 kW on average across a mixed workload: inference runs at 110 to 150 kW, training at 130 to 180. The rack count follows directly.
racks = 80 MW × 1,000 ÷ 145 kW = 552 GPUs = 552 × 72 = 39,744The building is about ≈216,000 SF, 600 by 360 ft, with 4 data halls of about ≈24,000 SF each. The site is about ≈140 acres, most of it the chiller yard: 620 by 400 ft, with ≈60 chillers of 630 tons on a 62 ft grid, air-cooled, N+1, with integrated free cooling. Electrical distribution is ≈60 line-ups of 2 MW, distributed redundant in a 5-to-make-4 arrangement. Liquid cooling captures 93% of the heat at the chip; the residual is airside, for network and storage. Staffing is 24 to 30 people.
The building's domestic water, for the people in it, is about ≈2,000 L/day. Divided over the users it serves that is 0.7 µL per user-day, and it is the only water term the narrative does not bother to draw.
2. The power
Power usage effectiveness is total facility energy divided by IT energy. A PUE of 1.20 means that for every kilowatt-hour the computers use, the building uses another 0.20 for cooling, power conversion and lighting. It is a ratio of energies over a period, so the number depends on the period.
The peak design PUE of this building is 1.35 PUE: the W32 design lane, five-year extreme ambient, 100% IT load. That is what the chillers are sized for and it is not an operating point. Annualized, with free cooling available whenever the outdoor air is below the 32 °C facility supply temperature, the design lands at 1.20 PUE. The headline scenario uses 1.20, inside that band and slightly conservative. For comparison, Uptime Institute's industry average is 1.52 PUE, flat for seven years; hyperscale fleets report 1.08 to 1.12 PUE; Google's fleet reports 1.09 PUE; new AI builds land at 1.15 to 1.25 PUE.
This design pays for its zero water in electricity. Dry cooling costs an additional 0.30 to 0.74 kWh/kWh per kWh of IT load against evaporative cooling, and that electricity has its own water footprint at the plant. Section 5 counts it.
3. The tokens
Energy per user depends on how many tokens the fleet actually processes per second, which is much lower than the benchmark number. Start from a benchmark blended throughput of 500,000 tok/s per rack and derate it three times, each factor named.
| Step | Factor | Result, tok/s per rack |
|---|---|---|
| Benchmark blended throughput | 500,000 | |
| Serving duty cycle: diurnal peak-to-average, time-to-first-token SLA headroom, spare capacity | 0.65× | 325,000 |
| Inference share of the compute block: training, RL and evals draw full power and yield no user tokens | 0.70× | 227,500 |
| Real traffic versus benchmark recipe: imperfect batching, ragged context | 0.90× | 205,000 |
| Fleet average | 2.5÷ | 200,000 |
Reality anchor. OpenAI has stated it processes 15.00 billion tokens/min on the API, which is 21.60 trillion tokens/day. At 200,000 tok/s per rack that is ≈1,250 racks, roughly ≈181 MW of GB300 compute. OpenAI's actual fleet is far larger, for three reasons that do not undermine the model: most of the installed base is Hopper and Ampere, and NVIDIA cites 90 tok/s per GPU on Hopper against 6,000 tok/s per GPU on GB300, a 67× gap; training consumes an enormous share; and they are building for future demand. The model here describes what a modern inference fleet costs per token, which is the question a per-person figure needs answered.
4. The user
A day of AI use is taken as 8,000 tokens processed. Processed tokens include the prompt, the context the model re-reads on every turn, any hidden reasoning tokens, and the output. That is far more than the words on screen, and it is why this figure is a fair one for a person who sends about ≈4 substantial prompts a day with some back-and-forth. It is also why the per-prompt spread in published figures is so wide: a reasoning model can spend thousands of hidden tokens on one answer.
Wh per user-day = tokens × (100 MW × PUE ÷ 110.00 million tok/s) ÷ 3,600 = 8,000 × (100,000,000 W × 1.20 ÷ 110,000,000) ÷ 3,600 = 2.42 WhThe whole-facility 100 MW is used, not the 80 MW compute block, because the storage and network that yield no tokens still draw power on the user's behalf. Users served by one building: 9.50 trillion tokens ÷ 8,000 = ≈1.19 billion users.
Per prompt, the same day is 0.605 Wh at datacenter scope, and 0.47 mL of water at roughly 700 processed tokens per query, the basis used in the almond correction in Act 7. Published anchors bracket this: Google's own measurement of the median Gemini Apps text prompt, May 2025, is 0.24 Wh at datacenter scope, excluding network, device and training own disclosure; Sam Altman's stated average ChatGPT query is 0.34 Wh own disclosure; EPRI's estimate for a ChatGPT prompt is 2.9 Wh against 0.3 Wh for a traditional search independent estimate; reported GPT-5 averages run to ≈18 Wh with heavy responses to 40 Wh third-party estimate.
Worked example, live
Scenario: Average modern AI build. These inputs are shared with the story page. Changing them here changes the receipt in part 6 there.
Wh = 8,000 × (100,000,000 × 1.20 ÷ 110,000,000) ÷ 3,600 = 2.42 Wh on site = 0.50 L/kWh × (Wh ÷ PUE) = 1.01 mL at the plant = 1.8 L/kWh × Wh = 4.35 mL water = 5.36 mL per user-day year = 0.88 kWh, 1.96 L, about ≈6 cents, about 8.3 cups of water television = 91 s electricity, 112 s water, at 1.60 Wh and 2.88 mL per minuteThe cost line uses 0.068 $/kWh, the price implied by "about six cents" at 0.88 kWh, roughly a US industrial tariff. A residential tariff about doubles the cents and changes nothing else on the site.
5. The water
Water use effectiveness is liters of water consumed on site per kilowatt-hour of IT load. It counts evaporation from cooling towers and adiabatic pre-coolers, and it counts nothing upstream. An air-cooled, closed-loop building has a WUE near 0.0 L/kWh: the coolant loop is sealed and the chillers reject heat to air. The headline scenario uses 0.50 L/kWh, an average for a modern hybrid build, deliberately not the reference design's zero.
The larger term is indirect. Thermoelectric generation evaporates water in its own cooling towers, and hydro reservoirs evaporate water from their surface. The US thermal-fleet average used throughout is 1.8 L/kWh. Alternatives, all adjustable above: 1.2 L/kWh for a gas combined-cycle heavy grid; 3.1 L/kWh from Li, Yang, Islam and Ren; and 4.5 L/kWh for the 2023 US national figure including reservoir evaporation, which is 211.00 billion gallons against 176 TWh.
At the headline assumptions the split is 1.01 mL on site and 4.35 mL at the plant: 19% and 81%. Indirect dominates in every scenario, which is why Google's site-only 0.26 mL per prompt and Sam Altman's site-only 0.32 mL per query are both smaller than the figures here. Shaolei Ren of UC Riverside criticised the Google figure for excluding generation water. The criticism is correct, it applies equally to the Altman figure, and it is why this site counts grid water in every row.
| Scenario | PUE | WUE | Grid | Wh | Water, mL (site / plant) |
|---|---|---|---|---|---|
| Best-in-class new build, gas and wind grid | 1.15 | 0.10 | 1.2 | 2.32 | 2.98 (0.20 / 2.78) |
| Average modern AI build, headline | 1.20 | 0.50 | 1.8 | 2.42 | 5.36 (1.01 / 4.35) |
| Reference design as built | 1.20 | 0.0 | 1.8 | 2.42 | 4.35 (0 / 4.35) |
| Legacy evaporative, hot climate | 1.40 | 1.80 | 1.8 | 2.82 | 8.70 (3.63 / 5.08) |
| Evaporative plus hydro-heavy grid | 1.40 | 1.80 | 4.5 | 2.82 | 16.31 (3.63 / 12.69) |
The worst scenario on the table is 16.31 mL, about three times the headline. It is still under a tablespoon. The dry-cooling trade is the honest one: about ≈2.15 L/kWh saved on site per kWh of IT load, for 0.30 to 0.74 kWh/kWh of extra electricity, which at 1.8 L/kWh evaporates roughly 0.5 to 1.3 L per kWh of IT load at the plant. A net saving of water, paid in electricity, and the reason the narrative says air cooling moves water rather than eliminating it.
The landscape: AWS reports 0.12 L/kWh fleet-wide, from 0.02 L/kWh in Stockholm to 2.85 L/kWh in Jakarta, a 140× spread inside one operator. Equinix reports 0.91 L/kWh. Microsoft's regional figures include 0.02 L/kWh in Singapore and 1.52 L/kWh in Arizona; see the notes in the appendix on what could and could not be confirmed against Microsoft's own documents. The legacy industry average is 1.8 to 1.9 L/kWh. Best-in-class runs under < 0.05. Nevada's rule is the Southern Nevada Water Authority's moratorium on evaporative cooling in new commercial and industrial buildings; Singapore's roadmap sets a target of 2 L/kWh or lower.
6. The comparisons
The television
The site's unit is one minute of a 96 W television. That wattage is not chosen here; it is reverse-derived from Google's own framing that a 0.24 Wh prompt is "less than nine seconds of TV" (0.24 Wh ÷ 9 s × 3,600 = 96 W). The site is extending Google's unit, not inventing one. Google's water framing, "about five drops", implies the same site-only scope as its 0.26 mL.
per minute, set only: 96 W × 60 s = 1.60 Wh; 0.0016 kWh × 1.8 L/kWh = 2.88 mL per minute, full chain: 400 Wh ÷ 180 min = 2.22 Wh; 730 mL ÷ 180 min = 4.06 mL| Pairing | AI day | Electricity | Water |
|---|---|---|---|
| Datacenter-only AI against the set's own draw | 2.42 Wh / 5.36 mL | 91 seconds | 112 seconds |
| Full delivery chain, both sides | 3.4 Wh / 7 mL | 92 seconds | 105 seconds |
| Full-chain AI against a set-only television scope mismatch, refused | 3.4 Wh / 7 mL | 128 seconds | 146 seconds |
Every consistent pairing lands between 90 and 112 seconds. The mismatched pairing reaches 146 seconds and breaks the two-minute claim, which is exactly the kind of scope mixing that this page criticises in others. The scope field in the dataset prevents the narrative from rendering it; the comparison function refuses the pairing rather than labelling it.
The digital day
The full-chain rows in Act 5 split each activity into device, network and datacenter. Streaming uses the IEA allocation of 72% devices, 23% network and 5% datacenters, anchored on the same 96 W television for three hours: 288 Wh on the set. Network intensity is the weakest input: 0.02 kWh/GB fixed and 0.06 kWh/GB mobile, the 2019 IEA range halved for efficiency gains since. Published kWh/GB estimates span an order of magnitude, and the uncertainty runs in AI's favor: older, higher figures make streaming look worse, not AI. The social media datacenter figure, 13 Wh, is Meta's disclosed datacenter electricity divided by daily active people. Usage is 2 h 21 min h of social media a day globally and about ≈7 h of total US screen time. Device draws implied by those rows, ≈3 W for a phone and 30 W for a laptop, are reused for this page's footprint below.
The objects
Almond. 3.56 L per nut, slightly under a gallon, as attributed in press coverage to a 2019 USGS-affiliated study. The Fulton, Norton and Shilling paper linked in the appendix reports about 12 L per kernel on a different basis; if that basis were used, every almond comparison on the site would move further in AI's favor. The figure used is the smaller one.
Hamburger. The narrative says "a fast-food hamburger" and this page gives the basis: a McDonald's hamburger, 1.6 oz raw patty (45 g) plus bun and condiments. At the global-average beef footprint of 15,400 L/kg (Mekonnen and Hoekstra, 2012) the patty alone is about 700 L and the sandwich about 800 L; at a US feedlot figure it is about 330 L. ≈500 L is the planning central and the range is carried on the figure.
Delivery. One parcel, from the sorting depot to the door. The drive is a class 4 diesel step van on a suburban route, UPS-derived: 100 miles, 151 packages, 8.7 gallons of diesel, 7.8 MJ per parcel, which this site converts to 2.2 kWh (Stolaroff et al., 2018). The same paper gives the carrier's facilities, from UPS's 2015 company-wide totals divided by packages delivered: 0.35 kWh of electricity and 0.93 MJ of natural gas per package, 0.26 kWh as energy. Together, 2.81 kWh. Only the facility electricity carries power-plant water, 630 mL at the site's grid intensity. The warehouse that stored the item, the packaging and the long-haul leg are not counted; no defensible per-parcel figure exists for them, and each would make the parcel larger. An electric truck on the same route is 0.72 kWh at the plug; a small electric van on a dense city route is 0.13 kWh (Rodrigues et al., 2022); a gasoline van at half a mile between stops is 1.0 to 1.6 kWh well-to-wheel (Li, Kim and Keoleian, 2021). No carrier publishes a per-parcel energy figure.
Grid water for electric things. Anything electric on the story page gets its water the same way the AI figure does: the electricity times 1.8 L/kWh. A phone charge is 23 mL; boiling the water for a cup of coffee, 23.7 Wh, is 43 mL; heating a shower is 4.1 L; an electric-car mile is 540 mL.
Coffee, two ways. The 140 L per cup on the story page is the total footprint, almost all of it rain on the plantation. Water Footprint Network's own split puts the pumped share at about 1.0 L per cup, from 139 cubic meters per tonne of roasted coffee at 7 grams a cup. The story page uses the total, as it does for the hamburger, and says so.
Toilet. 6 L per flush matches the federal maximum of 1.6 gal in force since 1994. WaterSense toilets use 1.28 gallons or less; older toilets up to 6.
Shower. 65 L for eight minutes, and 2,270 Wh to heat it. Coffee, egg, bread, t-shirt. Water Footprint Network product footprints: 140 L, 200 L, 40 L, 2,700 L. Streaming hour. ≈133 Wh, one third of the three-hour row.
Blue versus green. Blue water is withdrawn from rivers, lakes and aquifers and consumed. Green water is rainfall held in the soil and transpired by plants. The comparison objects are total footprints, blue and green together; the AI figure is blue plus generation water. That mismatch is labelled in Act 2 and it runs against AI. The distinction matters most for beef in Section 7.
The almond correction
The widely circulated figure of 38,000 queries per almond does not reconcile with Altman's own 0.32 mL per query: 3.56 L ÷ 0.32 mL = 11,125 queries. Reaching 38,000 needs 0.094 mL per query, 3.4× lower than stated. This site's model at 0.47 mL per query gives about ≈7,500 queries. Directionally the claim is right; the arithmetic as quoted is not; and scoped consistently on site against the Act 4 reference design the ratio is infinite, so the argument is stronger than it was made.
7. The aggregate
US annual blue water, national scale, same metric. All US datacenters in 2023, direct plus indirect: 0.80 trillion L (LBNL). US golf courses, 2024 data: 1.59 trillion L, from GCSAA's 1.63 million acre-feet applied, net of the 21% reclaimed share. California almonds alone: 2.59 trillion L from 2.1 million acre-feet applied, or 4.70 trillion L on the higher footprint estimate. US beef, blue water only: 6.76 trillion L. US beef, total footprint including rainfall on pasture: 62.4 trillion L, of which most is green water and would have fallen regardless. Per US resident on 340.00 million people: datacenters 2,353 L, golf 4,672 L, almonds 7,619 L, beef 19,897 L.
Vintage and verification. LBNL reports about 66 billion liters direct and nearly 800 billion liters indirect for 2023, so the 0.80 figure matches the indirect term and understates the total by roughly 8%. That understatement runs in AI's favor and is recorded on the figure rather than corrected silently, because the brief's number is the one the narrative was built on. LBNL's 2025 Update, published June 2026, puts 2024 at 192 TWh (4.7%), 2028 at 464 TWh, and 2030 at 649 TWh; the original brief's 1,050 TWh for 2030 was BCG's high case and is no longer used. Rystad projects datacenter water consumption could roughly triple by 2030, with 34% of direct consumption in high-water-stress regions. S&P Global finds 43% of datacenters globally already exposed to high water stress.
datacenters in year y = 0.80 × (1 + (≈3 − 1) × (y − 2023) ÷ 7); passes golf (1.59) in 2,026On a straight line to triple, the datacenter bar passes golf in 2,026 and reaches 2.40 trillion L in 2030, still below almonds and well below beef's blue water. The story page says so in one sentence rather than leaving it to a critic.
Electricity, national
All US datacenters used 176 TWh in 2023, 4.4% of US electricity by LBNL's count, which excludes cryptocurrency mining. Against retail sales of 3,874 TWh the share is 4.5%. The story page sets that beside three household uses nobody proposes to switch off, from the EIA's 2020 Residential Energy Consumption Survey: home air conditioning 254 TWh (6.6% of retail sales), electric water heaters 156 TWh (4.0%), electric clothes dryers 56 TWh (1.4%). The household figures are 2020 survey data against 2023 sales, which the story page states. LBNL's 2025 Update projects 464 TWh for 2028 and 649 TWh for 2030, a range of 521 to 843 TWh.
chips' share of a datacenter's electricity = 1 ÷ PUE = 1 ÷ 1.20 = 83%; the rest, 17%, is cooling, power conversion and lightsHousehold bills: the evidence in both directions
The story page says a datacenter can raise household bills and that it depends on where you live. Four findings stand behind that, chosen because each comes from a government body, a national laboratory or an independent market monitor.
Virginia. The state's legislative auditor projected that a typical Dominion household's generation and transmission charges could be $14 to $37 a month higher by 2040, in constant dollars, depending on how much demand arrives. The same report found that datacenters "are currently paying full cost of service, but growing energy demand is likely to increase costs for other customers." It covers one utility and one part of the bill. As a yearly amount it is $168 to $444 a year; the figure is the increase in the monthly bill by 2040, not a total over the period.
Proportion. The US average residential price rose from 13.15 cents/kWh in 2020 to 17.30 cents/kWh in 2025, 32% before inflation. The Energy Information Administration does not attribute a share of that to datacenters; its own analysis points to capital spending on aging generation and delivery infrastructure. In Virginia, the regulator's November 2025 order raised the typical residential bill by $11.24 a month for 2026 without attributing the increase to datacenters. Datacenters are one driver of bills among several, and the story page says so.
The mid-Atlantic grid. PJM's independent market monitor attributes $29.4 billion, 46.2% of capacity charges across the last four auctions, to datacenter demand, existing and forecast. These are wholesale costs from a counterfactual simulation, and they reach household bills to different degrees by state and utility. The monitor's widely quoted larger percentages are increases over its simulated no-datacenter case, not shares of the total, and are not used here.
The other direction. Lawrence Berkeley National Laboratory and Brattle found that load growth "has tended to depress retail electricity prices in recent years, by spreading fixed costs over greater load": 0.6 cents/kWh lower for a 10% rise in a state's use from 2019 to 2024, a pattern their April 2026 update found still held through 2025. Households benefited less than businesses, and the authors warn the past "need not be prelude," naming PJM as the counter-example.
Rules adopted since 2025. Ohio's commission approved a tariff for new datacenters in July 2025; Indiana's approved large-load terms in February 2025; Georgia's adopted a rule in January 2025; Virginia's created a separate rate class in November 2025. Each requires long contracts and minimum payments. In June 2026 the Federal Energy Regulatory Commission ordered all six regional grid operators to justify or reform how they connect large loads and recover their costs.
Not used, and why. No primary source gives a national dollars-per-household figure, so none appears. A consumer advocate's per-month estimates for Maryland describe the whole capacity price jump, not the datacenter share. Savings claimed by utilities, an industry-funded preprint finding that datacenters lowered rates, a law school paper arguing costs are being shifted, and a Federal Reserve Bank of Dallas working paper estimating a rise in wholesale prices are all informative and all contested; they are named here rather than quoted on the story page.
8. What would change these conclusions
- The per-person figure is small. It would move materially if fleet throughput were below about 50,000 tok/s per rack (a further 4× derate), if a typical day were above about 50,000 processed tokens, or if the median user were on a reasoning model at 18 Wh per prompt. Any of those would put a typical day at 10 to 45 minutes of television. None would put it at an hour of streaming.
- The water is at the power plant. It would be false for a building with WUE above about 2.5 L/kWh on a low-water grid, such as an evaporative build in a hot climate on gas combined-cycle. Those buildings exist and are the ones being banned.
- AI loses to golf on a national scale. It stops being true in 2,026 on the straight line above, and earlier if LBNL's direct term is added. The site says so.
- The two-minute claim. It would fail if the television were materially less than 96 W (a 40 W set makes the day about four minutes of it), if the 8,000-token day were doubled, or if a mismatched pairing were allowed. The first two are honest disagreements about the median; the third is not allowed.
- Siting. Nothing here would change the conclusion that averages do not answer a local question, because the site does not claim they do.
Appendix: every figure
Each row is the entry behind a clickable number on the narrative page. Scope tags: datacenter-only counts the building and, where stated, the generating plant; full-chain adds device and network; device-only is the appliance's own draw; blue-water and total-water are the hydrological scopes. Kind tags distinguish a company's own disclosure from an independent estimate and from figures derived on this site.
| Figure | Value | Scope, kind | Source | Derivation and notes |
|---|---|---|---|---|
bldg-critical-itcritical IT capacity | 100 MW | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | |
bldg-compute-shareshare of critical IT to GPU compute | 80% | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | The other 20% is storage and network. |
bldg-compute-mwGPU compute block | 80 MW | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | 100 MW × 80%inputs: bldg-critical-it, bldg-compute-share |
rack-poweraverage rack power, GB300 NVL72 | 145 kW 110 to 180 | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | Training 130 to 180 kW, inference 110 to 150 kW. |
racksGB300 NVL72 racks | 552 racks | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | 80,000 kW ÷ 145 kWinputs: bldg-compute-mw, rack-power |
gpus-per-rackGPUs per NVL72 rack | 72 GPUs | datacenter-only own-disclosure | NVIDIA, 2025. GB300 NVL72 inference throughput versus Hopper verified 2026-10-01 | |
gpusGPUs in the reference building | 39,744 GPUs | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | 552 × 72inputs: racks, gpus-per-rack |
pue-peakpeak design PUE | 1.35 PUE | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | W32 lane, 5-year extreme ambient, 100% IT load. An upper bound, not an operating point. |
pue-annualannualized PUE, reference design | 1.20 PUE 1.15 to 1.22 | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | Free cooling at 32 °C facility supply. The headline scenario uses 1.20, inside this band. |
wue-referenceWUE of the reference design | 0.0 L/kWh | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | Closed-loop direct liquid cooling, air-cooled chillers, no evaporative makeup. Approximately zero on site. |
chillersair-cooled chillers | ≈60 chillers | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | 630-ton each, N+1, six blocks of ten, integrated free cooling. |
chiller-tonschiller capacity, each | 630 tons | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | |
lineupsmodular electrical line-ups | ≈60 line-ups | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | Distributed redundant, 5-to-make-4. |
lineup-mwelectrical line-up rating, each | 2 MW | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | |
heat-captureliquid heat capture, nominal | 93% 88 to … | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | 88% minimum. The residual 12% is airside, for network and storage. |
bldg-areabuilding area | ≈216,000 SF | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | |
hallsdata halls | 4 halls | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | |
hall-areaarea per data hall | ≈24,000 SF | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | |
bldg-lengthbuilding length | 600 ft | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | |
bldg-widthbuilding width | 360 ft | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | |
site-acressite area | ≈140 acres | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | |
yard-lengthchiller yard length | 620 ft | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | |
yard-widthchiller yard width | 400 ft | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | |
chiller-gridchiller plant grid spacing | 62 ft | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | |
staffstaff on site | 24 to 30 people … to 30 | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | 24/7/365. |
domestic-wateron-site domestic water, whole building | ≈2,000 L/day | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | |
domestic-water-per-userdomestic water per user-day | 0.7 µL | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | 2,000 L ÷ 1.19 billion usersinputs: domestic-water, users-daily |
tok-benchmarkbenchmark blended throughput | 500,000 tok/s per rack | datacenter-only own-disclosure | NVIDIA, 2025. GB300 NVL72 inference throughput versus Hopper verified 2026-10-01 | |
derate-dutyserving duty cycle | 0.65× | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | Diurnal peak-to-average, time-to-first-token SLA headroom, spare capacity. |
derate-inferenceinference share of the compute block | 0.70× | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | Training, RL and evals draw full power and yield no user tokens. |
derate-trafficreal traffic versus benchmark recipe | 0.90× | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | Imperfect batching, ragged context. |
derate-totaltotal derate | 2.5÷ | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 1 ÷ (0.65 × 0.70 × 0.90)inputs: derate-duty, derate-inference, derate-traffic |
tok-fleetfleet-average throughput | 200,000 tok/s per rack | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 500,000 ÷ 2.5inputs: tok-benchmark, derate-total |
fleet-tok-sfleet throughput | 110.00 million tok/s | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 552 racks × 200,000 tok/sinputs: racks, tok-fleet |
fleet-tok-dayfleet tokens per day | 9.50 trillion tokens/day | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 110 M tok/s × 86,400 sinputs: fleet-tok-s |
tokens-per-user-daytokens processed per user per day | 8,000 tokens | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | Processed tokens: prompt, context, hidden reasoning, and output. Not words on screen. |
users-dailydaily users served by one reference building | ≈1.19 billion users | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 9.5 trillion ÷ 8,000inputs: fleet-tok-day, tokens-per-user-day |
prompts-per-dayprompts in an 8,000-token day | ≈4 prompts | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
openai-tok-minOpenAI API throughput, stated, March 2026 | 15.00 billion tokens/min | datacenter-only own-disclosure | OpenAI, 2026. Accelerating the next phase of AI, 31 March 2026: over 15 billion tokens per minute on the API (6 billion was stated at DevDay, October 2025) verified 2026-10-01 | 6 billion per minute was the figure stated in October 2025. |
openai-tok-dayOpenAI API tokens per day | 21.60 trillion tokens/day | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 15 billion × 1,440 mininputs: openai-tok-min |
openai-racks-equivGB300 racks to serve OpenAI API volume | ≈1,250 racks | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 21.6 trillion ÷ 86,400 ÷ 200,000inputs: openai-tok-day, tok-fleet |
openai-mw-equivGB300 compute to serve OpenAI API volume | ≈181 MW | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 1,250 racks × 145 kWinputs: openai-racks-equiv, rack-power |
hopper-tok-gpuHopper inference throughput | 90 tok/s per GPU | datacenter-only own-disclosure | NVIDIA, 2025. GB300 NVL72 inference throughput versus Hopper verified 2026-10-01 | |
gb300-tok-gpuGB300 inference throughput | 6,000 tok/s per GPU | datacenter-only own-disclosure | NVIDIA, 2025. GB300 NVL72 inference throughput versus Hopper verified 2026-10-01 | |
hopper-gapGB300 to Hopper throughput gap | 67× | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 6,000 ÷ 90inputs: gb300-tok-gpu, hopper-tok-gpu |
puePUE, average modern AI build | 1.20 PUE | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
wueWUE, average modern AI build | 0.50 L/kWh | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
grid-watergrid water intensity, US thermal average | 1.8 L/kWh | datacenter-only government | USGS, 2023. Thermoelectric water consumption, reanalysis 2008 to 2020; per-kWh intensities derived from consumption and generation verified 2026-10-01 | Water evaporated at the generating plant per kWh delivered. The largest single term in the water figure. |
grid-water-ccgtgrid water intensity, gas combined-cycle heavy | 1.2 L/kWh | datacenter-only government | USGS, 2023. Thermoelectric water consumption, reanalysis 2008 to 2020; per-kWh intensities derived from consumption and generation verified 2026-10-01 | |
grid-water-ligrid water intensity, Li et al. | 3.1 L/kWh | datacenter-only academic | Li, Yang, Islam and Ren, 2023. Making AI Less Thirsty: uncovering and addressing the secret water footprint of AI models verified 2026-10-01 | |
grid-water-us2023grid water intensity, US national 2023 including hydro reservoir evaporation | 4.5 L/kWh | datacenter-only government | Lawrence Berkeley National Laboratory, 2024. 2024 United States Data Center Energy Usage Report (176 TWh and 4.4% in 2023, and the water figures); for electricity, superseded by the 2025 Update of June 2026 verified 2026-10-01 | 211 billion gallons ÷ 176 TWhinputs: dc-water-us-gallons, dc-twh-2023 |
dc-water-us-gallonsUS datacenter water, direct plus indirect, 2023 | 211.00 billion gallons | datacenter-only government | Lawrence Berkeley National Laboratory, 2024. 2024 United States Data Center Energy Usage Report (176 TWh and 4.4% in 2023, and the water figures); for electricity, superseded by the 2025 Update of June 2026 verified 2026-10-01 | 211 billion gallons is about 800 billion L, which LBNL reports as the indirect (power plant) term for 2023. |
ai-day-whone day of AI use, electricity | 2.42 Wh | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 8,000 tokens × (100 MW × 1.20 PUE ÷ 110 M tok/s) ÷ 3,600inputs: tokens-per-user-day, bldg-critical-it, pue, fleet-tok-s |
ai-day-mlone day of AI use, water | 5.36 mL | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | site 1.01 mL + grid 4.35 mLinputs: ai-day-ml-site, ai-day-ml-grid Datacenter scope: cooling water on site plus water evaporated at the power plant to make the electricity. Excludes network, device, training, and fab water. |
ai-day-ml-siteone day of AI use, water consumed on site | 1.01 mL | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 0.50 L/kWh × (2.42 Wh ÷ 1.20)inputs: wue, ai-day-wh, pue |
ai-day-ml-gridone day of AI use, water evaporated at the power plant | 4.35 mL | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 1.8 L/kWh × 2.42 Whinputs: grid-water, ai-day-wh |
ai-day-site-shareshare of the water consumed on site | 19% | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 1.01 ÷ 5.36inputs: ai-day-ml-site, ai-day-ml |
ai-day-grid-shareshare of the water evaporated at the power plant | 81% | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 4.35 ÷ 5.36inputs: ai-day-ml-grid, ai-day-ml |
ai-year-kwhone year of daily AI use, electricity | 0.88 kWh | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 2.42 Wh × 365inputs: ai-day-wh |
ai-year-lone year of daily AI use, water | 1.96 L | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 5.36 mL × 365inputs: ai-day-ml |
ai-year-centsone year of daily AI use, electricity cost | ≈6¢ | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 0.88 kWh × priceinputs: ai-year-kwh, price-kwh |
price-kwhelectricity price used for the cost line | 0.068 $/kWh | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | Implied by the brief's "about six cents" at 0.88 kWh. Roughly a US industrial tariff. Adjustable; a residential tariff roughly doubles the cents and changes nothing else. |
ai-year-almondsone year of daily AI use, in almonds | 0.55 almonds | total-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 1.96 L ÷ 3.56 Linputs: ai-year-l, almond-l |
sc-best-puebest-in-class new build, PUE | 1.15 PUE | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
sc-best-wuebest-in-class new build, WUE | 0.10 L/kWh | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
sc-best-whbest-in-class new build, per user-day | 2.32 Wh | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
sc-best-mlbest-in-class new build, water per user-day | 2.98 mL | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | Site 0.20 mL, grid 2.78 mL at 1.2 L/kWh (gas and wind grid). |
sc-legacy-puelegacy evaporative, hot climate, PUE | 1.40 PUE | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
sc-legacy-wuelegacy evaporative, hot climate, WUE | 1.80 L/kWh | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
sc-legacy-whlegacy evaporative, per user-day | 2.82 Wh | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
sc-legacy-mllegacy evaporative, water per user-day | 8.70 mL | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | Site 3.63 mL, grid 5.08 mL. |
sc-hydro-mllegacy evaporative on a hydro-heavy grid, water per user-day | 16.31 mL | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | Site 3.63 mL, grid 12.69 mL at 4.5 L/kWh. |
sc-bod-mlreference design as built, water per user-day | 4.35 mL | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | Site 0, grid 4.35 mL. |
gemini-whGoogle, median Gemini Apps text prompt, electricity | 0.24 Wh | datacenter-only own-disclosure | Google, 2025. Measuring the environmental impact of AI inference (median Gemini Apps text prompt, May 2025) verified 2026-10-01 | Includes idle provisioning and datacenter overhead. Excludes network, device, training, and storage. |
gemini-mlGoogle, median Gemini Apps text prompt, water | 0.26 mL | datacenter-only own-disclosure | Google, 2025. Measuring the environmental impact of AI inference (median Gemini Apps text prompt, May 2025) verified 2026-10-01 | Site cooling water only. Excludes water evaporated at the power plant, which this site counts. |
google-pueGoogle fleet PUE | 1.09 PUE | datacenter-only own-disclosure | Google, 2025. Measuring the environmental impact of AI inference (median Gemini Apps text prompt, May 2025) verified 2026-10-01 | |
google-tv-secondsGoogle's own framing: one prompt is less than this many seconds of television | 9 seconds | datacenter-only own-disclosure | Google, 2025. Measuring the environmental impact of AI inference (median Gemini Apps text prompt, May 2025) verified 2026-10-01 | Implies a 96 W television. This site adopts that unit. |
google-dropsGoogle's own framing: one prompt is about this many drops of water | ≈5 drops | datacenter-only own-disclosure | Google, 2025. Measuring the environmental impact of AI inference (median Gemini Apps text prompt, May 2025) verified 2026-10-01 | |
altman-whSam Altman, average ChatGPT query, electricity | 0.34 Wh | datacenter-only own-disclosure | Sam Altman, 2025. The Gentle Singularity (blog post) verified 2026-10-01 | Blog post, not peer reviewed. Datacenter scope. |
altman-mlSam Altman, average ChatGPT query, water | 0.32 mL | datacenter-only own-disclosure | Sam Altman, 2025. The Gentle Singularity (blog post) verified 2026-10-01 | On-site water only. Excludes generation water. |
epri-chatgpt-whEPRI, one ChatGPT prompt | 2.9 Wh | datacenter-only independent-estimate | EPRI, 2024. Powering Intelligence: Analyzing Artificial Intelligence and Data Center Energy Consumption verified 2026-10-01 | |
epri-search-whEPRI, one traditional web search | 0.3 Wh | datacenter-only independent-estimate | EPRI, 2024. Powering Intelligence: Analyzing Artificial Intelligence and Data Center Energy Consumption verified 2026-10-01 | |
gpt5-whreported GPT-5 average per response | ≈18 Wh | datacenter-only independent-estimate | Press reports, 2025. Reported per-response energy of GPT-5, University of Rhode Island AI lab estimates verified 2026-10-01 | Third-party estimate. Some responses reported to 40 Wh. |
gpt5-heavy-whreported GPT-5 heavy response | 40 Wh | datacenter-only independent-estimate | Press reports, 2025. Reported per-response energy of GPT-5, University of Rhode Island AI lab estimates verified 2026-10-01 | |
model-spreadspread between the lowest and highest published per-prompt figures | 75× | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 18 Wh ÷ 0.24 Whinputs: gpt5-wh, gemini-wh |
heavy-user-tv-mina heavy reasoning user's day, in minutes of television | 45 minutes | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 4 prompts × 18 Wh ÷ 1.60 Wh per minuteinputs: prompts-per-day, gpt5-wh, tv-min-wh |
dd-ai-deviceAI assistant, device | 0.5 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-ai-networkAI assistant, network | 0.5 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-ai-dcAI assistant, datacenter | 2.4 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-ai-whAI assistant, 8,000 tokens, about 4 prompts, full chain | 3.4 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-ai-mlAI assistant, full chain, water | 7 mL | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-ai-dcshareAI assistant, datacenter share of energy | 71% | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-email-deviceemail, device | 30 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-email-networkemail, network | 1 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-email-dcemail, datacenter | 1 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-email-whemail, 1 hour in a client, about 120 messages, full chain | 32 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-email-mlemail, full chain, water | 58 mL | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-email-dcshareemail, datacenter share | 3% | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-web-deviceweb browsing, device | 45 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-web-networkweb browsing, network | 6 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-web-dcweb browsing, datacenter | 1.5 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-web-whweb browsing, 1.5 hours on a laptop, full chain | 53 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-web-mlweb browsing, full chain, water | 95 mL | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-web-dcshareweb browsing, datacenter share | 3% | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-social-devicesocial media, device | 7 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-social-networksocial media, network | 59 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-social-dcsocial media, datacenter | 13 Wh | datacenter-only own-disclosure | Meta, 2024. Sustainability report, datacenter electricity, divided by daily active people verified 2026-10-01 | |
dd-social-whsocial media, 2 h 21 min on a phone, full chain | 79 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-social-mlsocial media, full chain, water | 149 mL | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-social-dcsharesocial media, datacenter share | 16% | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-stream-devicestreaming video, device (television) | 288 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 96 W × 3 hinputs: tv-watts |
dd-stream-networkstreaming video, network | 92 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-stream-dcstreaming video, datacenter and CDN | 20 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-stream-whstreaming video, 3 hours HD on a television, full chain | 400 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-stream-mlstreaming video, full chain, water | 730 mL | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-stream-dcsharestreaming video, datacenter share | 5% | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-stream-hourshours of streaming in the digital day | 3 h | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dd-social-hoursdaily time on social media, global | 2 h 21 min h | full-chain independent-estimate | DataReportal, 2025. Digital 2025, daily time on social media verified 2026-10-01 | DataReportal's Digital 2026 report measures social and video feeds together at about 2 h 39 min a day, a different definition; the 2025 like-for-like figure is kept. |
us-screen-hourstotal daily US screen time | ≈7 h | full-chain independent-estimate | DataReportal, 2025. Digital 2025, daily time on social media verified 2026-10-01 | |
dd-stream-screenshow many more screen-widths the streaming bar runs past the social media bar | 4 screens | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | floor(400 ÷ 79) − 1inputs: dd-stream-wh, dd-social-wh |
an-ai-kwhAI, annual, full chain | 1.3 kWh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 3.4 Wh × 365inputs: dd-ai-wh |
an-ai-lAI, annual water, full chain | 2.7 L | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
an-email-kwhemail, annual | 12 kWh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
an-email-lemail, annual water | 21 L | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
an-web-kwhweb browsing, annual | 19 kWh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
an-web-lweb browsing, annual water | 35 L | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
an-social-kwhsocial media, annual | 29 kWh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
an-social-lsocial media, annual water | 54 L | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
an-stream-kwhstreaming, annual | 146 kWh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
an-stream-lstreaming, annual water | 267 L | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
an-nonai-kwhcombined non-AI digital life, annual electricity | 206 kWh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 12 + 19 + 29 + 146inputs: an-email-kwh, an-web-kwh, an-social-kwh, an-stream-kwh |
an-nonai-lcombined non-AI digital life, annual water | 377 L | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 21 + 35 + 54 + 267inputs: an-email-l, an-web-l, an-social-l, an-stream-l |
ai-addswhat AI adds to a non-AI digital life | 0.6% | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 1.3 kWh ÷ 206 kWhinputs: an-ai-kwh, an-nonai-kwh |
iea-device-sharestreaming energy share, devices (IEA allocation) | 72% | full-chain independent-estimate | IEA, 2020. The carbon footprint of streaming video: fact-checking the headlines verified 2026-10-01 | |
iea-network-sharestreaming energy share, network (IEA allocation) | 23% | full-chain independent-estimate | IEA, 2020. The carbon footprint of streaming video: fact-checking the headlines verified 2026-10-01 | |
iea-dc-sharestreaming energy share, datacenters (IEA allocation) | 5% | full-chain independent-estimate | IEA, 2020. The carbon footprint of streaming video: fact-checking the headlines verified 2026-10-01 | |
net-fixednetwork intensity, fixed | 0.02 kWh/GB | full-chain independent-estimate | IEA, 2020. The carbon footprint of streaming video: fact-checking the headlines verified 2026-10-01 | 2019 IEA range halved for efficiency gains. Published estimates span an order of magnitude. Older, higher figures make streaming look worse, not AI. |
net-mobilenetwork intensity, mobile | 0.06 kWh/GB | full-chain independent-estimate | IEA, 2020. The carbon footprint of streaming video: fact-checking the headlines verified 2026-10-01 | |
phone-wattsphone draw while in use | ≈3 W | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 7 Wh ÷ 2.35 h, from the social media rowinputs: dd-social-device, dd-social-hours |
laptop-wattslaptop draw while browsing | 30 W | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 45 Wh ÷ 1.5 h, from the web browsing rowinputs: dd-web-device |
flush-lone toilet flush | 6 L | device-only government | US EIA, 2024. Average residential electricity consumption, and thermoelectric generation verified 2026-10-01 | |
almond-lone California almond | 3.56 L | total-water academic | USGS-affiliated study, 2019, as reported, 2019. Per-nut almond water footprint, 3.56 L; the Fulton, Norton and Shilling 2019 paper linked here reports about 12 L per kernel on a different basis verified 2026-10-01 | Attribution note: press coverage credits a 2019 USGS-affiliated study. The Fulton, Norton and Shilling 2019 paper reports about 12 L per kernel on a different basis, which would make every almond comparison on this site more favorable to AI, not less. Slightly under a gallon. Full embedded-water footprint. |
bread-lone slice of bread | 40 L | total-water academic | Water Footprint Network, 2011. Product water footprints (bread, coffee, egg, cotton) verified 2026-10-01 | |
shower-lone 8-minute shower | 65 L | device-only government | US EIA, 2024. Average residential electricity consumption, and thermoelectric generation verified 2026-10-01 | |
coffee-lone cup of coffee | 140 L | total-water academic | Water Footprint Network, 2011. Product water footprints (bread, coffee, egg, cotton) verified 2026-10-01 | |
egg-lone egg | 200 L | total-water academic | Water Footprint Network, 2011. Product water footprints (bread, coffee, egg, cotton) verified 2026-10-01 | |
burger-lone fast-food hamburger | ≈500 L 330 to 800 | total-water academic | Mekonnen and Hoekstra, 2012. A global assessment of the water footprint of farm animal products, Ecosystems verified 2026-10-01 | 1.6 oz raw patty (45 g) plus bun and condiments. About 800 L at the global-average beef footprint of 15,400 L/kg, about 330 L at a US feedlot figure. 500 L is the planning central. |
beef-l-kgglobal-average beef water footprint | 15,400 L/kg | total-water academic | Mekonnen and Hoekstra, 2012. A global assessment of the water footprint of farm animal products, Ecosystems verified 2026-10-01 | |
tshirt-lone cotton t-shirt | 2,700 L | total-water academic | Water Footprint Network, 2011. Product water footprints (bread, coffee, egg, cotton) verified 2026-10-01 | |
flush-daysone toilet flush, in AI user-days | 1,120 AI days | total-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 6 L ÷ 5.36 mLinputs: flush-l, ai-day-ml |
almond-daysone almond, in AI user-days | 665 AI days | total-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 3.56 L ÷ 5.36 mLinputs: almond-l, ai-day-ml |
almond-yearsone almond, in years of daily AI use | 1.8 AI years | total-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 665 ÷ 365inputs: almond-days |
shower-daysone shower, in AI user-days | 12,130 AI days | total-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
shower-yearsone shower, in years of daily AI use | 33 AI years | total-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
burger-daysone hamburger, in AI user-days | 93,330 AI days | total-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 500 L ÷ 5.36 mLinputs: burger-l, ai-day-ml |
burger-yearsone hamburger, in years of daily AI use | 256 AI years | total-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
tshirt-yearsone t-shirt, in years of daily AI use | 1,380 AI years | total-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
led-wha 10 W LED bulb for one hour | 10 Wh | device-only government | US EIA, 2024. Average residential electricity consumption, and thermoelectric generation verified 2026-10-01 | |
phone-charge-whcharging a phone | 13 Wh | device-only government | US EIA, 2024. Average residential electricity consumption, and thermoelectric generation verified 2026-10-01 | |
boil-whboiling a liter of water | 100 Wh | device-only government | US EIA, 2024. Average residential electricity consumption, and thermoelectric generation verified 2026-10-01 | |
stream-hour-whone hour of HD streaming, full chain | ≈133 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 400 Wh ÷ 3 hinputs: dd-stream-wh |
ev-mile-whone mile in an electric car | 300 Wh | device-only government | US EIA, 2024. Average residential electricity consumption, and thermoelectric generation verified 2026-10-01 | |
burger-whone fast-food hamburger, primary energy | ≈1,100 Wh | total-water academic | Mekonnen and Hoekstra, 2012. A global assessment of the water footprint of farm animal products, Ecosystems verified 2026-10-01 | |
fridge-day-wha refrigerator for one day | 1,500 Wh | device-only government | US EIA, 2024. Average residential electricity consumption, and thermoelectric generation verified 2026-10-01 | |
hot-shower-whone 8-minute hot shower | 2,270 Wh | device-only government | US EIA, 2024. Average residential electricity consumption, and thermoelectric generation verified 2026-10-01 | |
home-day-whan average US home for one day | 29,000 Wh | device-only government | US EIA, 2024. Average residential electricity consumption, and thermoelectric generation verified 2026-10-01 | EIA's 2024 figure is about 28,400 Wh a day (865 kWh a month); the brief's 29,000 is kept. |
altman-almond-claimChatGPT queries per almond, widely circulated version of the claim | 38,000 queries | datacenter-only press | PolitiFact, 2026. Fact check of Sam Altman's remark on the Sources podcast, 1 September 2026, that one almond equals 38,000 ChatGPT queries (rated Mostly False), 4 September 2026 verified 2026-10-01 | |
almond-queries-altmanqueries per almond at Altman's own 0.32 mL | 11,125 queries | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 3.56 L ÷ 0.32 mLinputs: almond-l, altman-ml |
altman-implied-mlper-query water implied by 38,000 queries per almond | 0.094 mL | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 3.56 L ÷ 38,000inputs: almond-l, altman-almond-claim |
altman-gapgap between the implied figure and the stated figure | 3.4× | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 0.32 ÷ 0.094inputs: altman-ml, altman-implied-ml |
site-ml-per-querywater per query, this site's bottom-up model | 0.47 mL | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | Datacenter scope including generation water, at roughly 700 processed tokens per query. |
site-queries-per-almondqueries per almond, this site's model | ≈7,500 queries | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 3.56 L ÷ 0.47 mLinputs: almond-l, site-ml-per-query |
wue-bestbest-in-class facilities, WUE | < 0.05 L/kWh | datacenter-only industry-survey | Uptime Institute, 2026. Global Data Center Survey 2026 (industry average PUE 1.52; 1.54 in 2025, 1.56 in 2024, 1.58 in 2023) verified 2026-10-01 | |
wue-awsAWS fleet-wide WUE, 2025 | 0.12 L/kWh | datacenter-only own-disclosure | Amazon Web Services, 2025. AWS water positive: WUE by region, 2025 report verified 2026-10-01 | |
wue-aws-stockholmAWS, Stockholm, WUE | 0.02 L/kWh | datacenter-only own-disclosure | Amazon Web Services, 2025. AWS water positive: WUE by region, 2025 report verified 2026-10-01 | |
wue-aws-jakartaAWS, Jakarta, WUE | 2.85 L/kWh | datacenter-only own-disclosure | Amazon Web Services, 2025. AWS water positive: WUE by region, 2025 report verified 2026-10-01 | |
wue-aws-spreadspread inside AWS's own portfolio | 140× | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 2.85 ÷ 0.02inputs: wue-aws-jakarta, wue-aws-stockholm |
wue-equinixEquinix WUE, 2025 | 0.91 L/kWh | datacenter-only own-disclosure | Equinix, 2025. Sustainability data summary (0.95 all sites in 2024 data; the 0.91 figure is as reported by Rystad, October 2025) verified 2026-10-01 | Secondary reports of Equinix's own 2025 data give 0.91 across all sites and 1.41 at evaporatively cooled sites. As reported by Rystad Energy, October 2025. Equinix's own 2024 data summary states 0.95 across all sites. |
wue-google-msftGoogle and Microsoft fleet WUE | well under 1.0 L/kWh | datacenter-only own-disclosure | Microsoft, 2026. 2026 Environmental Sustainability Report (FY25): global datacenter WUE 0.27 L/kWh; regional WUE at datacenters.microsoft.com/sustainability/efficiency verified 2026-10-01 | |
wue-msft-singaporeMicrosoft, Singapore, WUE | 0.02 L/kWh | datacenter-only own-disclosure | Microsoft, 2026. 2026 Environmental Sustainability Report (FY25): global datacenter WUE 0.27 L/kWh; regional WUE at datacenters.microsoft.com/sustainability/efficiency verified 2026-10-01 | Could not be located in a Microsoft document during verification; Microsoft publishes regional WUE (EMEA 0.03, APAC 0.25, Americas 0.34 for FY25). Treat the site-level figure as unconfirmed. |
wue-msft-arizonaMicrosoft, Arizona, WUE | 1.52 L/kWh | datacenter-only own-disclosure | Microsoft, 2026. 2026 Environmental Sustainability Report (FY25): global datacenter WUE 0.27 L/kWh; regional WUE at datacenters.microsoft.com/sustainability/efficiency verified 2026-10-01 | Could not be located in a Microsoft document during verification. Treat as unconfirmed. |
wue-legacylegacy industry average WUE | 1.8 to 1.9 L/kWh … to 1.9 | datacenter-only industry-survey | Uptime Institute, 2026. Global Data Center Survey 2026 (industry average PUE 1.52; 1.54 in 2025, 1.56 in 2024, 1.58 in 2023) verified 2026-10-01 | |
wue-aircooledair-cooled closed loop, on site | ≈0.0 L/kWh | datacenter-only derived | Reference Architecture, 2026. Basis of Design, 100 MW GB300 NVL72 facility, Rev 03-S verified 2026-10-01 | |
pue-globalindustry average PUE, 2026 survey | 1.52 PUE | datacenter-only industry-survey | Uptime Institute, 2026. Global Data Center Survey 2026 (industry average PUE 1.52; 1.54 in 2025, 1.56 in 2024, 1.58 in 2023) verified 2026-10-01 | 1.52 in 2026, 1.54 in 2025, 1.56 in 2024, 1.58 in 2023: flat for seven years. |
pue-hyperscalehyperscale fleet PUE | 1.08 to 1.12 PUE … to 1.12 | datacenter-only industry-survey | Uptime Institute, 2026. Global Data Center Survey 2026 (industry average PUE 1.52; 1.54 in 2025, 1.56 in 2024, 1.58 in 2023) verified 2026-10-01 | |
pue-new-ainew AI builds, PUE | 1.15 to 1.25 PUE … to 1.25 | datacenter-only industry-survey | Uptime Institute, 2026. Global Data Center Survey 2026 (industry average PUE 1.52; 1.54 in 2025, 1.56 in 2024, 1.58 in 2023) verified 2026-10-01 | |
singapore-wue-capSingapore WUE ceiling for new datacenters | 2 L/kWh | datacenter-only government | Singapore IMDA, 2024. Green Data Centre Roadmap, May 2024: WUE target of 2.0 m³/MWh or lower verified 2026-10-01 | The roadmap states a target of 2.0 m³/MWh or lower for new and existing facilities, not a hard ceiling on new builds. |
dry-cooling-water-savedwater saved on site by dry cooling, per kWh of IT load | ≈2.15 L/kWh | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dry-cooling-energy-costadditional electricity for dry cooling, per kWh of IT load | 0.30 to 0.74 kWh/kWh … to 0.74 | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | That electricity has its own water footprint at the power plant. Dry cooling moves water rather than eliminating it. |
nevada-banNevada: cooling towers for new datacenters | banned | datacenter-only government | Southern Nevada Water Authority, 2025. Moratorium on evaporative cooling in new commercial and industrial buildings, in force for permits from 31 August 2023 verified 2026-10-01 | The rule is the Southern Nevada Water Authority's moratorium on evaporative cooling in new commercial and industrial buildings, which covers datacenters, not a state statute. |
agg-dcall US datacenters, 2023, direct plus indirect | 0.80 trillion L | datacenter-only government | Lawrence Berkeley National Laboratory, 2024. 2024 United States Data Center Energy Usage Report (176 TWh and 4.4% in 2023, and the water figures); for electricity, superseded by the 2025 Update of June 2026 verified 2026-10-01 | Verification note: LBNL reports about 66 billion L direct and nearly 800 billion L indirect for 2023; 0.80 trillion matches the indirect term alone, so the total is understated by roughly 8%. That understatement runs in AI's favor and is flagged rather than hidden. Direct cooling water plus water evaporated at power plants to make their electricity. |
agg-golfUS golf courses, 2024 | 1.59 trillion L | blue-water industry-survey | GCSAA, 2024. Golf Course Environmental Profile Phase IV water report, 2024 data verified 2026-10-01 | 1.63 million acre-feet is 2.01 trillion L; net of the 21% reclaimed share it is 1.59 trillion L of fresh blue water. GCSAA's 2024 data puts the recycled share at 19%. 1.63 million acre-feet, 21% of it reclaimed water. |
agg-almondsCalifornia almonds alone | 2.59 trillion L | total-water academic | USGS-affiliated study, 2019, as reported, 2019. Per-nut almond water footprint, 3.56 L; the Fulton, Norton and Shilling 2019 paper linked here reports about 12 L per kernel on a different basis verified 2026-10-01 | 2.1 million acre-feet applied. |
agg-almonds-highCalifornia almonds, higher footprint estimate | 4.70 trillion L | total-water academic | USGS-affiliated study, 2019, as reported, 2019. Per-nut almond water footprint, 3.56 L; the Fulton, Norton and Shilling 2019 paper linked here reports about 12 L per kernel on a different basis verified 2026-10-01 | |
agg-beef-blueUS beef, blue water only | 6.76 trillion L | blue-water academic | USDA and Water Footprint Network, 2012. US beef production and per-kilogram water footprint, blue and total verified 2026-10-01 | |
agg-beef-totalUS beef, total footprint including rainfall | 62.4 trillion L | total-water academic | USDA and Water Footprint Network, 2012. US beef production and per-kilogram water footprint, blue and total verified 2026-10-01 | Mostly green water: rain that fell on pasture and would have fallen regardless. |
agg-golf-xgolf versus datacenters | 2.0× | blue-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 1.59 ÷ 0.80inputs: agg-golf, agg-dc |
agg-almonds-xalmonds versus datacenters | 3.2× | blue-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
agg-almonds-high-xalmonds, high estimate, versus datacenters | 5.9× | blue-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
agg-beef-blue-xbeef, blue water, versus datacenters | 8.5× | blue-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
agg-beef-total-xbeef, total footprint, versus datacenters | 78× | total-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
us-populationUS population | 340.00 million people | blue-water government | US Census Bureau, 2024. US population estimate, 340 million verified 2026-10-01 | The Vintage 2025 estimate is 341.8 million; 340 million is kept to match the 2023 aggregates. |
pc-dcdatacenters, per US resident per year | 2,353 L | blue-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 0.80 trillion ÷ 340 millioninputs: agg-dc, us-population |
pc-golfgolf, per US resident per year | 4,672 L | blue-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
pc-almondsCalifornia almonds, per US resident per year | 7,619 L | blue-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
pc-beefbeef, blue water, per US resident per year | 19,897 L | blue-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
dc-twh-2023US datacenter electricity, 2023 | 176 TWh | datacenter-only government | Lawrence Berkeley National Laboratory, 2024. 2024 United States Data Center Energy Usage Report (176 TWh and 4.4% in 2023, and the water figures); for electricity, superseded by the 2025 Update of June 2026 verified 2026-10-01 | Kept as the base year because it matches the latest LBNL water data; 2024 was 192 TWh and 4.7%. |
dc-twh-2030US datacenter electricity, 2030, LBNL reference case | 649 TWh 521 to 843 | datacenter-only government | Lawrence Berkeley National Laboratory, 2026. United States Data Center Energy Usage Report: 2025 Update, LBNL-2001758, June 2026 verified 2026-10-01 | LBNL's 2025 Update gives 649 TWh for 2030, range 521 to 843 (9.5% to 15.3% of US electricity). The original brief's 1,050 TWh was BCG's high case as cited by WRI and is no longer used. |
dc-water-growthprojected growth in datacenter water consumption by 2030 | ≈3× | blue-water independent-estimate | Rystad Energy, 2025. Data center water consumption outlook to 2030 verified 2026-10-01 | |
dc-stress-shareshare of direct datacenter water consumption in high-water-stress regions | 34% | blue-water independent-estimate | Rystad Energy, 2025. Data center water consumption outlook to 2030 verified 2026-10-01 | |
dc-stress-globaldatacenters globally already exposed to high water stress | 43% | blue-water independent-estimate | S&P Global, 2025. Data centers and water stress exposure verified 2026-10-01 | |
agg-year-basebase year of the aggregate figures | 2,023 | datacenter-only government | Lawrence Berkeley National Laboratory, 2024. 2024 United States Data Center Energy Usage Report (176 TWh and 4.4% in 2023, and the water figures); for electricity, superseded by the 2025 Update of June 2026 verified 2026-10-01 | |
agg-year-projprojection year | 2,030 | datacenter-only government | Lawrence Berkeley National Laboratory, 2024. 2024 United States Data Center Energy Usage Report (176 TWh and 4.4% in 2023, and the water figures); for electricity, superseded by the 2025 Update of June 2026 verified 2026-10-01 | |
tv-wattsthe television | 96 W | device-only own-disclosure | Google, 2025. Measuring the environmental impact of AI inference (median Gemini Apps text prompt, May 2025) verified 2026-10-01 | Reverse-derived from Google's framing that a 0.24 Wh prompt is "less than nine seconds of TV". This site extends Google's unit rather than inventing one. |
tv-min-whone minute of television, electricity, set only | 1.60 Wh | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 96 W × 60 sinputs: tv-watts |
tv-min-mlone minute of television, water, set only | 2.88 mL | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 0.0016 kWh × 1.8 L/kWhinputs: tv-min-wh, grid-water |
tv-min-wh-fullone minute of television, electricity, full chain | 2.22 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 400 Wh ÷ 180 mininputs: dd-stream-wh |
tv-min-ml-fullone minute of television, water, full chain | 4.06 mL | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 730 mL ÷ 180 mininputs: dd-stream-ml |
claim-wh-dcone AI day in television, electricity, datacenter scope against the set's own draw | 91 seconds | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 2.42 Wh ÷ 1.60 Wh per minute × 60inputs: ai-day-wh, tv-min-wh |
claim-ml-dcone AI day in television, water, datacenter scope against the set's own draw | 112 seconds | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 5.36 mL ÷ 2.88 mL per minute × 60inputs: ai-day-ml, tv-min-ml |
claim-wh-fullone AI day in television, electricity, full chain both sides | 92 seconds | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 3.4 Wh ÷ 2.22 Wh per minute × 60inputs: dd-ai-wh, tv-min-wh-full |
claim-ml-fullone AI day in television, water, full chain both sides | 105 seconds | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 7 mL ÷ 4.06 mL per minute × 60inputs: dd-ai-ml, tv-min-ml-full |
claim-lowlowest consistent pairing | 90 seconds | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
claim-highhighest consistent pairing | 112 seconds | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | |
mismatch-whfull-chain AI against a set-only television, electricity (scope mismatch) | 128 seconds | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 3.4 Wh ÷ 1.60 Wh per minute × 60inputs: dd-ai-wh, tv-min-wh Not a valid pairing. Shown only to demonstrate what scope mixing does. |
mismatch-mlfull-chain AI against a set-only television, water (scope mismatch) | 146 seconds | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 7 mL ÷ 2.88 mL per minute × 60inputs: dd-ai-ml, tv-min-ml Not a valid pairing. It breaks the two-minute claim, which is exactly why the site refuses to render it. |
five-min-tv-whfive minutes of television, electricity | 8.0 Wh | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 5 × 1.60 Whinputs: tv-min-wh |
five-min-tv-mlfive minutes of television, water | 14.4 mL | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 5 × 2.88 mLinputs: tv-min-ml |
five-min-tv-daysfive minutes of television, in days of AI use | ≈3 AI days | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 8.0 Wh ÷ 2.42 Wh; 14.4 mL ÷ 5.36 mLinputs: five-min-tv-wh, ai-day-wh |
dd-stream-screens-waterhow many more screen-widths the streaming water bar runs past the social media bar | 3 screens | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | floor(730 ÷ 149) − 1inputs: dd-stream-ml, dd-social-ml |
site-wh-per-promptone prompt, this site's model, datacenter scope | 0.605 Wh | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 2.42 Wh ÷ 4 promptsinputs: ai-day-wh, prompts-per-day |
site-ml-per-promptone prompt, this site's model, water, datacenter scope | 1.34 mL | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 5.36 mL ÷ 4 promptsinputs: ai-day-ml, prompts-per-day |
chain-wh-per-promptdevice and network electricity per prompt | 0.25 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | (0.5 + 0.5 Wh) ÷ 4 promptsinputs: dd-ai-device, dd-ai-network, prompts-per-day |
chain-ml-per-promptdevice and network water per prompt | 0.41 mL | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | (7 − 5.36 mL) ÷ 4 promptsinputs: dd-ai-ml, ai-day-ml, prompts-per-day |
stream-hour-mlone hour of HD streaming, water, full chain | 243 mL | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 730 mL ÷ 3 hinputs: dd-stream-ml, dd-stream-hours |
social-hour-whone hour of social media, full chain | 34 Wh | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 79 Wh ÷ 2.35 hinputs: dd-social-wh, dd-social-hours |
social-hour-mlone hour of social media, water, full chain | 63 mL | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 149 mL ÷ 2.35 hinputs: dd-social-ml, dd-social-hours |
agg-dc-2030US datacenters, 2030, at roughly triple | 2.40 trillion L | blue-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 0.80 × 3inputs: agg-dc, dc-water-growth |
agg-dc-passes-golfyear the datacenter bar passes golf on a straight line to triple | 2,026 | blue-water derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 2023 + 7 × (1.59 ÷ 0.80 − 1) ÷ 2inputs: agg-dc, agg-golf, dc-water-growth |
us-teaspoonone US teaspoon | 4.93 mL | device-only government | NIST, 2026. Handbook 44, units of volume verified 2026-10-01 | |
us-gallonone US gallon | 3.785 L | device-only government | NIST, 2026. Handbook 44, units of volume verified 2026-10-01 | |
us-cupone US cup | 236.6 mL | device-only government | NIST, 2026. Handbook 44, units of volume verified 2026-10-01 | |
water-bottleone 16.9-ounce bottle of water | 500 mL | device-only derived | Retail standard, 2026. Standard 16.9 fl oz (500 mL) bottled water verified 2026-10-01 | |
bottle-daysone bottle of water, in days of AI use | 93 AI days | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 500 mL ÷ 5.36 mLinputs: water-bottle, ai-day-ml |
football-fieldone football field including end zones | 57,600 SF | device-only industry-survey | NFL, 2025. Official playing rules, field dimensions verified 2026-10-01 | 360 ft × 160 ft |
bldg-fieldsthe building, in football fields | 3.75 football fields | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 216,000 SF ÷ 57,600 SFinputs: bldg-area, football-field |
homes-per-rackaverage US homes drawing as much power as one rack | 120 homes | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 145 kW ÷ (29,000 Wh ÷ 24 h)inputs: rack-power, home-day-wh |
meme-ratiohow far the 17-gallons-per-question claim is from this site's per-query figure | 137,000× | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 17 gal × 3.785 L ÷ 0.47 mLinputs: us-gallon, site-ml-per-query |
meme-gallonsthe circulated claim: gallons per question | 17 gal | datacenter-only press | Circulated claim, 2025. Viral posts, 2023 to 2025, unattributed verified 2026-10-01 | |
persona-light-wh"a little": one question a day, datacenter scope | 0.605 Wh | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 1 × 0.605 Whinputs: site-wh-per-prompt |
persona-light-ml"a little": one question a day, water | 1.34 mL | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 1 × 1.34 mLinputs: site-ml-per-prompt |
persona-heavy-wh"all day for work": four long answers from a heavy reasoning model, datacenter scope | 72 Wh | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 4 × 18 Whinputs: prompts-per-day, gpt5-wh |
persona-heavy-ml"all day for work": water | ≈160 mL | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 0.50 × (72 ÷ 1.20) + 1.8 × 72inputs: persona-heavy-wh, wue, pue, grid-water |
persona-heavy-usd"all day for work": a year of electricity | 1.79 $ | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 72 Wh × 365 × $0.068inputs: persona-heavy-wh, price-kwh |
stream-year-usda year of streaming, electricity | 9.93 $ | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 146 kWh × $0.068inputs: an-stream-kwh, price-kwh |
social-year-usda year of social media, electricity | 1.97 $ | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 29 kWh × $0.068inputs: an-social-kwh, price-kwh |
ai-year-usda year of AI, electricity, full chain | 0.09 $ | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 1.3 kWh × $0.068inputs: an-ai-kwh, price-kwh |
stream-year-showersa year of streaming, water, in 8-minute showers | 4.1 showers | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 267 L ÷ 65 Linputs: an-stream-l, shower-l |
ai-year-almonds-fulla year of AI, water, full chain, in almonds | 0.76 almonds | full-chain derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 2.7 L ÷ 3.56 Linputs: an-ai-l, almond-l |
parcel-diesel-kwhone parcel, last mile, diesel delivery truck on a suburban route, fuel energy | 2.2 kWh | lifecycle academic | Stolaroff et al., 2018. Energy use and life cycle GHG emissions of drones for commercial package delivery, Nature Communications 9:409 verified 2026-10-01 | Class 4 diesel step van, UPS-derived base case: 100 miles, 151 packages, 8.7 gallons of diesel; the paper states 7.8 MJ per package, which this site converts to 2.2 kWh. Fuel energy, not electricity, so no power-plant water applies. |
parcel-ev-kwh-highone parcel, last mile, electric delivery truck on the same suburban route | 0.72 kWh | lifecycle academic | Stolaroff et al., 2018. Energy use and life cycle GHG emissions of drones for commercial package delivery, Nature Communications 9:409 verified 2026-10-01 | 2.6 MJ per package at the plug. |
parcel-ev-kwh-lowone parcel, last mile, small electric van on a dense city route | 0.13 kWh | lifecycle academic | Rodrigues et al., 2022. Last-mile delivery emissions, Patterns 3:100569 verified 2026-10-01 | 0.47 MJ per package; 1.74 stops per km, two packages per stop. |
parcel-facility-kwhone parcel, the sorting and distribution facilities, electricity | 0.35 kWh | lifecycle academic | Stolaroff et al., 2018. Energy use and life cycle GHG emissions of drones for commercial package delivery, Nature Communications 9:409, Methods verified 2026-10-01 | UPS company-wide electricity for 2015 divided by 4.7 billion packages delivered; stated in the paper's Methods, "Emissions from warehouses". The paper treats it as a base case with acknowledged uncertainty in accounting boundaries. |
parcel-facility-gas-kwhone parcel, the facilities' natural gas, as energy | 0.26 kWh | lifecycle academic | Stolaroff et al., 2018. Energy use and life cycle GHG emissions of drones for commercial package delivery, Nature Communications 9:409, Methods verified 2026-10-01 | 0.93 MJ ÷ 3.6 The paper states 0.93 MJ of natural gas per package, same basis as the electricity. Fuel energy; no power-plant water applies. |
parcel-total-kwhone parcel, depot and last mile together, energy | 2.81 kWh | lifecycle derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 2.2 + 0.35 + 0.26inputs: parcel-diesel-kwh, parcel-facility-kwh, parcel-facility-gas-kwh Counts the sorting facilities and the final drive. Does not count the warehouse that stored the item, the packaging, or the long-haul trip; each would make it larger. |
parcel-facility-mlone parcel, water at the power plant for the facilities' electricity | 630 mL | lifecycle derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 0.35 kWh × 1.8 L/kWhinputs: parcel-facility-kwh, grid-water |
parcel-diesel-daysone diesel-delivered parcel, in days of AI, energy | 909 AI days | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 2,200 Wh ÷ 2.42 Whinputs: parcel-diesel-kwh, ai-day-wh |
parcel-ev-water-highone electric-truck parcel, water at the power plant | 1.3 L | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 0.72 kWh × 1.8 L/kWhinputs: parcel-ev-kwh-high, grid-water |
dc-share-usall US datacenters as a share of US electricity, 2023 | 4.4% | datacenter-only government | Lawrence Berkeley National Laboratory, 2024. 2024 United States Data Center Energy Usage Report (176 TWh and 4.4% in 2023, and the water figures); for electricity, superseded by the 2025 Update of June 2026 verified 2026-10-01 | Excludes cryptocurrency mining. Against retail sales alone the share is 4.5%. |
dc-twh-2028-lowUS datacenter electricity, 2028 projection, low (2024 report) | 325 TWh | datacenter-only government | Lawrence Berkeley National Laboratory, 2024. 2024 United States Data Center Energy Usage Report (176 TWh and 4.4% in 2023, and the water figures); for electricity, superseded by the 2025 Update of June 2026 verified 2026-10-01 | Superseded: the 2025 Update gives a 2028 reference case of 464 TWh. |
dc-twh-2028-highUS datacenter electricity, 2028 projection, high (2024 report) | 580 TWh | datacenter-only government | Lawrence Berkeley National Laboratory, 2024. 2024 United States Data Center Energy Usage Report (176 TWh and 4.4% in 2023, and the water figures); for electricity, superseded by the 2025 Update of June 2026 verified 2026-10-01 | Superseded: the 2025 Update gives a 2028 reference case of 464 TWh. |
dc-twh-2028US datacenter electricity, 2028, LBNL reference case | 464 TWh | datacenter-only government | Lawrence Berkeley National Laboratory, 2026. United States Data Center Energy Usage Report: 2025 Update, LBNL-2001758, June 2026 verified 2026-10-01 | |
dc-twh-2024US datacenter electricity, 2024 | 192 TWh | datacenter-only government | Lawrence Berkeley National Laboratory, 2026. United States Data Center Energy Usage Report: 2025 Update, LBNL-2001758, June 2026 verified 2026-10-01 | |
dc-share-us-2024all US datacenters as a share of US electricity, 2024 | 4.7% | datacenter-only government | Lawrence Berkeley National Laboratory, 2026. United States Data Center Energy Usage Report: 2025 Update, LBNL-2001758, June 2026 verified 2026-10-01 | |
us-retail-twhUS retail electricity sales, 2023 | 3,874 TWh | device-only government | US EIA, 2024. Electric Power Annual, table 2.2, sales to ultimate customers by sector verified 2026-10-01 | 2024 retail sales were 3,975 TWh; 2023 is kept so the shares are same-year with the datacenter figure. |
ac-twhUS home air conditioning, electricity, 2020 | 254 TWh | device-only government | US EIA, 2024. 2020 Residential Energy Consumption Survey, tables CE4.1 and CE5.1a verified 2026-10-01 | Occupied primary homes; air handlers for cooling are a further 38 TWh. |
waterheat-twhUS electric water heaters, electricity, 2020 | 156 TWh | device-only government | US EIA, 2024. 2020 Residential Energy Consumption Survey, tables CE4.1 and CE5.1a verified 2026-10-01 | |
dryer-twhUS electric clothes dryers, electricity, 2020 | 56 TWh | device-only government | US EIA, 2024. 2020 Residential Energy Consumption Survey, table CE5.1a verified 2026-10-01 | |
ac-sharehome air conditioning as a share of US retail sales | 6.6% | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 254 ÷ 3,874inputs: ac-twh, us-retail-twh 2020 survey against 2023 sales. |
waterheat-shareelectric water heaters as a share of US retail sales | 4.0% | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 156 ÷ 3,874inputs: waterheat-twh, us-retail-twh |
dryer-shareelectric clothes dryers as a share of US retail sales | 1.4% | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 56 ÷ 3,874inputs: dryer-twh, us-retail-twh |
it-shareshare of a datacenter's electricity that reaches the chips | 83% | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 1 ÷ 1.20 PUEinputs: pue |
overhead-shareshare of a datacenter's electricity for cooling, power conversion and lights | 17% | datacenter-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 1 − 1 ÷ 1.20inputs: pue |
kettle-cup-whboiling the water for one cup of coffee | 23.7 Wh | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 100 Wh per liter × 0.2366 Linputs: boil-wh, us-cup Assumes the cup is boiled from cold. |
coffee-blue-lone cup of coffee, blue water only | 1.0 L | blue-water academic | Mekonnen and Hoekstra, 2010. The green, blue and grey water footprint of crops and derived crop products, Value of Water Research Report 47 verified 2026-10-01 | 139 m³ per tonne roasted × 7 g The 140 L total is almost all rain on the plantation; about 0.7% is pumped water. |
flush-standard-galUS federal maximum flush volume since 1994 | 1.6 gal | blue-water government | US EPA, 2024. WaterSense: residential toilets verified 2026-10-01 | WaterSense toilets use 1.28 gallons or less; older toilets up to 6. |
bldg-homesaverage US homes drawing as much power as the whole building | ≈82,800 homes | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 100,000 kW ÷ (29 kWh per day ÷ 24 h)inputs: bldg-critical-it, home-day-wh |
phone-charge-mlcharging a phone, water evaporated at the power plant | 23 mL | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 13 Wh × 1.8 L/kWhinputs: phone-charge-wh, grid-water |
kettle-cup-mlboiling the water for one cup, water at the power plant | 43 mL | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 23.7 Wh × 1.8 L/kWhinputs: kettle-cup-wh, grid-water |
hot-shower-mlheating one shower, water at the power plant | 4.1 L | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 2,270 Wh × 1.8 L/kWhinputs: hot-shower-wh, grid-water |
ev-mile-mlone electric-car mile, water at the power plant | 540 mL | device-only derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | 300 Wh × 1.8 L/kWhinputs: ev-mile-wh, grid-water |
bill-va-2040projected rise in a typical Virginia household's generation and transmission charges by 2040, before inflation | $14 to $37 a month … to 37 | cost government | Virginia JLARC, 2024. Data Centers in Virginia, Report 598, 9 December 2024 verified 2026-10-01 | Dominion residential customer at 1,000 kWh a month, constant 2024 dollars: +$14 at half of unconstrained demand, +$37 at unconstrained demand. One utility, and only the generation and transmission part of the bill. The same report found that datacenters "are currently paying full cost of service, but growing energy demand is likely to increase costs for other customers". |
bill-va-2040-yearthe Virginia projection, as a yearly amount | $168 to $444 a year … to 444 | cost derived | This site, 2026. Bottom-up model, derived on the sources page verified 2026-10-01 | $14 × 12 to $37 × 12inputs: bill-va-2040 About 46 cents to $1.22 a day by 2040. Against the $90 a month these charges were in 2023, a rise of 16% to 41%. |
res-price-2020US average residential electricity price, 2020 | 13.15 cents/kWh | cost government | US EIA, 2026. Electric Power Monthly, table 5.3, average price of electricity to ultimate customers verified 2026-10-01 | |
res-price-2025US average residential electricity price, 2025 | 17.30 cents/kWh | cost government | US EIA, 2026. Electric Power Monthly, table 5.3, average price of electricity to ultimate customers verified 2026-10-01 | |
res-price-riserise in the US average residential electricity price, 2020 to 2025 | 32% | cost government | US EIA, 2025. Today in Energy, May 2025, on rising retail electricity prices verified 2026-10-01 | 17.30 ÷ 13.15 − 1 = 31.6%inputs: res-price-2025, res-price-2020 Not adjusted for inflation. EIA does not attribute a share of the rise to datacenters; its May 2025 analysis points to capital spending on aging generation and delivery infrastructure. |
va-scc-2026rise in the typical Dominion residential bill for 2026 approved by Virginia's regulator | $11.24 a month | cost government | Virginia State Corporation Commission, 2025. Final Order in the Dominion biennial review, PUR-2025-00058, 25 November 2025 verified 2026-10-01 | From the biennial review order, with a further $2.36 a month in 2027. The commission's release does not attribute the increase to datacenters. The same order created the separate rate class for very large customers. |
pjm-dc-shareshare of capacity charges across the last four PJM auctions tied to datacenter demand, existing and forecast | 46.2% | cost independent-estimate | Monitoring Analytics (PJM Independent Market Monitor), 2026. Market Monitor Report to the PJM Members Committee, 27 July 2026 verified 2026-10-01 | A counterfactual simulation by the market monitor that includes forecast load not yet built. Wholesale dollars, which reach household bills to different degrees by state and utility. PJM is the grid operator for 13 mid-Atlantic and midwestern states. |
pjm-dc-dollarscapacity charges across the last four PJM auctions tied to datacenter demand | $29.4 billion | cost independent-estimate | Monitoring Analytics (PJM Independent Market Monitor), 2026. Market Monitor Report to the PJM Members Committee, 27 July 2026 verified 2026-10-01 | Same basis and caveats as the 46.2% share. |
lbnl-load-pricefall in average retail price associated with a 10% rise in a state's electricity use, 2019 to 2024 | 0.6 cents/kWh | cost government | Lawrence Berkeley National Laboratory and Brattle, 2025. Factors Influencing Recent Trends in Retail Electricity Prices in the United States, October 2025 verified 2026-10-01 | Load growth "has tended to depress retail electricity prices in recent years, by spreading fixed costs over greater load". Residential customers benefited to a lesser extent, and the authors warn the relationship "need not always exist". The April 2026 update found it held through 2025. |
This site is independent. No organization named on it has reviewed or endorsed it. Company and product names are used only to identify the source of a published figure. All marks belong to their owners.
This page's own footprint
Measuring.
With scripting off this page cannot measure itself. Its transfer is a few hundred kilobytes; at 0.06 kWh/GB that is well under 2.42 Wh, and a few minutes on a ≈3 W phone adds about the same again.
Method: bytes transferred from the browser's own resource timing, times network intensity; plus time this page has been open, times the device draw implied by the digital-day rows. Server and CDN energy are not measured. If this figure ever exceeds a day of AI use, the build has failed its own budget and something must come out.